EXBATT
    EXBATT
    Containerized battery energy storage system on a concrete pad beside a substation.
    Products / BESS

    Battery energy storage, delivered turnkey.

    Containerized and modular BESS for C&I and utility sites. Peak shaving, backup, and renewable integration, with EMS, PCS, and long-term service included.

    Short answer

    A battery energy storage system, or BESS, is a battery bank combined with a power conversion system and an energy management system, able to charge and discharge on command to shave peaks, back up loads, and firm renewable generation. EXBATT delivers cabinet and containerised BESS turnkey in the Western Balkans, from feasibility and grid application through commissioning and long term service.

    Systems

    From 100 kWh cabinets to multi-MWh containers.

    Rack-based cabinets for commercial sites, containerized units for industrial and utility deployments. Fire-rated enclosures, integrated HVAC, and safety systems engineered for the site.

    Cabinet BESSContainerized MWhIntegrated HVAC and fire
    Use cases

    Peak shaving, backup, renewable integration.

    Reduce demand charges, ride through outages, and firm up PV or wind on the same site. Dispatch strategy tuned to the tariff, the load, and the generation profile.

    Peak shavingBackup powerPV firming
    Delivery

    Engineered, installed, and serviced by one team.

    Feasibility, single-line design, grid application support, civil coordination, commissioning, and O&M. No handoffs between vendors.

    • Feasibility and single-line design
    • Grid application and compliance support
    • Turnkey EPC delivery
    • Long-term O&M contracts

    Frequently asked

    What size BESS does a site need?
    Two numbers decide it: power in kilowatts, set by the largest peak to be shaved or the load to be carried, and energy in kilowatt hours, set by how long that must last. Efficiency losses and end of life capacity are added on top, usually 10 to 20 percent.
    How long does a BESS last?
    Lithium iron phosphate cells are typically warranted for 6000 cycles or 10 to 15 years to 70 or 80 percent of original capacity. Inverters and cooling are shorter lived and are treated as serviceable items in the maintenance plan.
    Can a BESS replace a generator?
    For short outages, yes, and without transfer delay or fuel. For outages measured in many hours or days, a generator still carries the energy, while the BESS covers the transition and reduces generator run time.